LAHomework Sign in
Los Angeles, CA 90027 · Ames St

2105 Ames St

Built 1938 · 2,193 sq ft
LOT 8,825 SQ FT · 1 STRUCTURE · APN 5591-004-005Lot Structure
Mark what has been done
Most homes this age have replaced a few systems already. Pick the year for each below and your timeline fills in.
Claiming homes opens soon on LAHomework.

We'll email you a one-time sign-in link.

What's on record

Year built
1938
Living area
2,193 sqft
Lot size
8,825 sqft
Structures on lot
1
Bedrooms
3
Bathrooms
2
Home type
Single-family
Parcel (APN)
5591-004-005

Major systems

No system details on record yet. When you claim your home you can add them in a minute.

See something wrong above? Report an error

Systems and what to plan for

0 worth planning for · 2 to confirm. Open "How we estimate this" on any card.
RoofOn record 2026
Expected 2046 to 2056From the 2026 permit
HVACConfirm the year
Probably replaced alreadyWhen was it done?
Water heaterConfirm the year
Probably replaced alreadyWhen was it done?

Estimates from public records and typical system lifespans. Not an inspection. Marking something as done resets that system's clock.

Nearby on this street

See all 21 homes on Ames St →

What does your home need?

Pick what you need, add your own, and we pass your list to a local contractor for each trade. They contact you. No cost, no obligation.

Coming up
Coming up
Get quotes

Sending your list saves it to this home and starts your record. You can manage it anytime.

Your home's update timeline

  • 2026
    permit on file, unconfirmedKitchen: 2 Bathroom(S).Bathroom Remodel For Residential Buildings (No Structural Changes).Kitchen Remodel For Residential Buildings (No Structural Changes).
  • 2026
    permit on file, unconfirmedGeneral remodel: Chimney Repair For Residential Buildings (Per City Standard Details).
  • 2026
    permit on fileGeneral remodel: Add Sill Plate Anchor Bolts And Plywood To Cripple Walls (If Existing) Per La City Standard Plan #1; No Foundation Replacement (Earthquake Hazard Reduction Per Chapter 92 Of The Los Angeles Building Code). (Houses, Residential Buildings Up To 3 Stories And Up To 4 Units).
  • 2026
    permit on fileRoof: Re-Roof With Class A Or B Roof Covering Material Weighing Less Than 6 Pounds Per Sq. Ft. Over New Solid Sheathing 30 Squares. Class A Roof Covering Is Required Within Very High Fire Hazard Severity Zone (Vhfhsz). For Residential Roof Replacement > 50% Of The Total Roof Area, Apply Cool Roof Product
  • 2026
    permit on file, unconfirmedBathrooms: Interior Alteration To (E) Single Family Dwelling To Demo/Install Interior Partitions And Reconfigure Floor Plan Layout Including A New Bathroom . Work Per Engineered Design .
  • 2026
    permit on file, unconfirmedElectrical: Service Change From Existing Overhead Service To New 200A 120/240V Single-Phase Main Panel. Relocate Electric Panel To Right Side Front Corner Of Garage Per Ladwp Service Planning (Work Request #3170786, Esr Diane Perez, 05/05/26). New 3'X3' Clear And Level Workspace At Panel Location, Plus New 125A
  • 2026
    permit on file, unconfirmedElectrical: Whole-House Rewire Of Existing Single-Family Dwelling: Replace All Branch Circuit Wiring From New 200A Main Panel And 125A Subpanel (Per Permit # 26041-90000-18737), Including General Lighting And Receptacle Circuits, Dedicated Appliance Circuits (Range, Dishwasher, Disposal, Laundry, Hvac), And Har
  • 2026
    permit on file, unconfirmedElectrical: Add Two (2) New 120V Branch Circuits From Existing Panel To Exterior Locationsserving An Outdoor Fire Pit And An Outdoor Bbq. Underground Runs In Pvc Conduit Atcode Burial Depth. Gfci-Protected Receptacles With Weatherproof In-Use Covers.Non-Engineered Wiring, Less Than 600 Volts, Existing Single Fa
  • 2026
    permit on file, unconfirmedPlumbing: Complete Repipe Of Existing Residence. Replace All Supply Lines And Drain/Waste/Vent Lines. No New Fixtures, No Structural Changes
  • 2026
    permit on file, unconfirmedHeating & cooling: Replace Existing Hvac System Including Furnace/Air Handler, Condenser Unit, And All Ductwork. Like-For-Like Replacement, No Structural Modifications.
  • 2026
    permit on file, unconfirmedPlumbing: Trenchless Rehabilitation Of Existing Sewer Lateral Via Cured-In-Place Pipe (Cipp) Lining Through Existing Cleanouts. Replacement Of House-To-Sewer Connection (Tie-In) At Building Exterior, Including New Abs/Cast Iron Lateral Pipe To Existing Cleanout. No Change In Fixture Count Or Pipe Routing.
  • 2026
    permit on file, unconfirmedPlumbing: Install One (1) New Outdoor Shower Fixture With Hot/Cold Water Supply Piping Anddrainage To Existing Sanitary Sewer. Install New Low-Pressure Gas Piping With Two (2)Outlets Serving An Outdoor Fire Pit And An Outdoor Bbq. Install Private Subsurfacefrench Drain / Area Drain System With On-Site Dischar

Manage this home to schedule a service or to update the timeline.